• Home
  • Southern New Hampshire University
  • Network Defense CYB-310-T5690
  • Network Reconfiguration and Planning

Network Reconfiguration and Planning

Southern New Hampshire University CYB 310 Network Reconfiguration Planning Template Complete this worksheet by replacing the bracketed text. Current Network State Sales Department . Four PCs . One switch Customer Service Department · Three PCS · One server · One switch Human Resources Department . Four PCs . One switch Backbone (Network Device Infrastructure) . Sales switch is connected to Office Router. . Customer Service switch is connected to Office Router. . Human Resources switch is connected to Office Router. · Office Router is connected to Edge Router. · Edge Router is connected to Edge Firewall. · Edge Firewall is connected to the WAN (Cloud). Network Reconfiguration (Future State) Customer Experience Department · 6 Desktop PC's (CE and Sales) · 1 Switch HR Department · 3 Desktop PC's · 1 Switch Network Servers · 2 Server's · 1 Switch · 2 Routers Backbone (Network Device Infrastructure) . CESwitch (Port 0) is connected to Core Router FastEthernet 0/1 . HRSwitch (Port1) is connected to Core Router Fast Ethernet 1/0 . ServerSwitch connected to ServerRouter FastEthernet 0/1 . EdgeFirewall connected to cloud . EdgeFirewall connected to BackboneSwitch Port 0 . CoreRouter FastEthernet 1/0 connected to BackboneSwitch Port 1 ServerRouter FastEthernet 0/0 connected to BackboneSwitch Port 2 . ServerRouter FastEthernet 0/1 connected to ServerSwitch 0/1 . WebServer connected to ServerSwitch Port 1 . AuthServer connected to ServerSwitch Port 2 Southern New Hampshire University . CustExpPC1 connected to CustExpSwitch Port 1 . CustExpPC2 connected to CustExpSwitch Port 2 . CustExpPC3 connected to CustExpSwitch Port 3 . CustExpPC4 connected to CustExpSwitch Port 4 . CustExpPC5 connected to CustExpSwitch Port 5 . CustExpPC6 connected to CustExpSwitch Port 6 . HRPC1 connected to HRSwitch Port 1 . HRPC2 connected to HRSwitch Port 2 . HRPC3 connected to HRSwitch Port 3 . WebServer firewall allows traffic from WAN on ports 80 HTTP and 443 HTTPS . WAN blocks traffic from other systems on ports 80 HTTP and 443 HTTPS . BackboneSwitches on VLAN 1 . CustEXP PCs on VLAN 2, IP Address 192.168.2.0/24, Subnet 255.255.255.0, Gateway 192.168.2.1 . HR PCs on VLAN 3, IP Address 192.168.3.0/24, Subnet 255.255.255.0, Gateway 192.168.3.1 . Servers will be on VLAN 4, IP Address 192.168.4.0/24, Subnet 255.255.255.0, Gateway 192.168.4.1