• Home
  • Southern New Hampshire University
  • Network Defense CYB-310-T5690
  • Network Defense CYB-310-T5690

Network Defense CYB-310-T5690

Southern New Hampshire University Walter Lawrence CYB 310 Network Reconfiguration Planning Current Network State Sales Department :3 PCs 1 switch Subnet 2 Department 3 PCs 1 switch Network 3 Department . 4 PCs 1 switch Server Network 3 . 1 PC 1 switch Server Main PC 1 server main PC Backbone (Network Device Infrastructure) Sales switch is connected to switch0 Subnet 2 switch is connected to pfsense4-2 Network 3 switch is connected to pfsense4-3 and R2 Server Network 3 switch is connected to R2 Server Main PC is connected to R1 Pfsense4-2 is connected to switch0 Pfsense4-3 is connected to switch0 R1 is connected to switch0 Switch0 is connected to pfsense4-1 Pfsense4-1 connected to the internet Network Reconfiguration (Future State) Customer Experience Department 6 PC's 1 switch HR Department :3 PC's 1 switch Network Servers : 2 servers : 1 switch :2 routers Backbone (Network Device Infrastructure) CustExpSwitch Port 0 is connected to CoreRouter FastEthernet 0/1 Southern New Hampshire University Backbone (Network Device Infrastructure)(Future Backbone (Network Device Infrastructure)(Future Site) Site) HRSwitch Port 1 connected CoreRouter FastEthernet :CustExpPC3 connected to CustExpSwitch Port 3 1/0 :CustExpPC4 connected to CustExpSwitch Port 4 ServerSwitch connected to ServerRouter FastEthernet :CustExpPC5 connected to CustExpSwitch Port 5 0/1 :CustExpPC6 connected to CustExpSwitch Port 6 CoreRouter FastEthernet 1/0 connected to :HRPC1 connected to HRSwitch Port 1 BackboneSwitch Port 1 HRPC2 connected to HRSwitch Port 2 ServerRouter FastEthernet 0/0 connected to HRPC3 connected to HRSwitch Port 3 BackboneSwitch Port 2 EdgeFirewall connected to BackboneSwitch Port 0 ServerRouter FastEthernet 0/1 connected to EdgeFirewall connected to cloud ServerSwitch 0/1 WebServer firewall allows traffic from WAN on ports WebServer connected to ServerSwitch Port 1 80 HTTP and 443 HTTPS AuthServer connected to ServerSwitch Port 2 WAN blocks traffic from other systems on ports 80 CustExpPC1 connected to CustExpSwitch Port 1 HTTP and 443 HTTPS CustExpPC2 connected to CustExpSwitch Port 2 CustomerEXP PCs on VLAN 2 HR PCs on VLAN 3 Southern New Hampshire University BackboneSwitches on VLAN 1 Both servers will be on VLAN 4 All computers, Network Routers and Edge Firewall's will be configured with designated IP addresses, subnet masks and Gatewa