One end of a 40 mm diameter, 500 mm long rod is welded to a steel support cylinder,
while at the other end, a 300 mm length steel bar is connected as shown in Figure Q9. A
load of 3 kN is acting vertically downwards at the end of the 300 mm length bar. Fillet
weld is placed around rod as indicated. Find the necessary weld size for the connection
between the rod and the cylinder. Take the weld material capacity to be 215 N/mm².
The arrangement should provide for a load factor of 1.8. [Ans. t = 15 mm]